FÖHR offers a comprehensive line of precision instruments designed for the analysis and condition assessment of insulating oils used in high-voltage power transformers.
Engineered for laboratories, utilities, and field service teams,
FOHR oil testing solutions deliver accuracy, reliability, and
repeatability in critical maintenance and diagnostic
applications.
Each instrument is designed to provide stable
measurements, intuitive operation, and consistent results,
even in demanding laboratory and industrial environments.
Transformer Oil Testers
FÖHR- V1301
TRANSFORMER OIL VISCOSITY
TESTER
Liquid bath holes:4
Range to control the temperature: indoor temperature—120°C
Precision to control the temperature: Room temperature -120°C≤±0.1°C
Room temperature -40°C≤±0.2°C
Input power source:AC220V±10V 50HZ
Heating power : 1000W
Test times : from 1 to 6 times , can adjust.
FÖHR- J3
OIL ACIDITY TESTER
Test range: 0.002~1mg KOH/g
Test error:≤±0.005mg KOH/g
Repeatability: ≤0.005mg
KOH/g 4)Ambient temperature: 10°C~45°C
Relative humidity(RH): ≤85%RH
Voltage supply: AC220V/50Hz
Power: 50W
FÖHR- C3
CLOSED CUP FLASH POINT TESTER
Temperature measuring range: -49.9°C~400.0°C
Temperature control range: room temperature~250°C
Repeatability: 0.029X(x=twice successive test average value)
Resolution: 0.1°C
Precision: 0.5%
Temperature Sensor: Platinum Resistor(PT100)
Flash fire detection: K Thermocouple
FÖHR-1B
DIELECTRIC OIL TESTER FOR TRANSFORMERS WITH VOLTAGE RANGE FROM 0 TO 100 KV
Output voltage: 0~100KV (optional)
Voltage distortion rate: <3% 3、Voltage raising speed: 0.5~5
KV/S (adjustable)
Standing time: 15min (adjustable) Boosting interval: 5 min (adjustable)
Boosting frequency:1~9time(s) (optional)
Booster capacity: 1.5KVA 8、Measuring accuracy:±3%
FÖHR- T3
AUTOMATIC OIL INTERFACIAL TENSION TESTER
Measuring range: 0-200mN/m
Accuracy:0.1%( test result)±0.1 mN/m
Precision:0.1mN/m
Sensibility:0.1mN/m
Main voltage:AC220V±20% 50HZ±10%
Maximum power dissipation:20W
Suit ambient temperature: 10~30°C(25°C the best)
FÖHR- W2
TRANSFORMER OIL MOISTURE TESTER
Current at the generator electrode: 100,200, 400 mA
Titration speed max: 40 ugH2O/s
Determination range 0 to200 mgH2O
Resolution 0.1 ug H2O
Reproducibility Sample: Reagent manufacturer's standard.With 10ug...1000 ug H2O: ± 2 ug
With >1000 ug H2O: 0.2% or better Drift compensation automatic
Display Graphical LCD, 240 x 128 dots,
LED back-lit
Autorized Distributor in Latin America
Monday & Company SA de CV
Av Real de Lomas 350-113
San Luis Potosí. Mexico.
info@mondayinstruments.com
+52 444 9188831
© 2025. FÖHR All rights reserved.
FÖHR Group Electrical Measurement Equipment
Office:Hermetschloostrasse 77 Zurich
ZH 8048 Switzerland.
Equipments Manufactured under
CE/ISO/CNAS/IAF CertifiCATIONS